Cleanroom standards tables: ISO 14644-1 and GMP Grades A–D

ISO 14644-1 classifies cleanrooms by the maximum number of particles per cubic metre. PIC/S GMP Annex 1 uses Grades A–D for sterile medicinal product manufacture. This page brings the most-used tables together in one place.
STANDARDS GUIDELIVE

ISO 14644-1:2015 particle limits ≥ 0.5 µm

ISO 5

3,520

ISO 6

35,200

ISO 7

352,000

ISO 8

3,520,000

ISO 9

35,200,000
Source: ISO 14644-1:2015 Table 1, particles per cubic metre · ISO Class 9 applies to the operational state only

GMP Grades under PIC/S GMP Annex 1 (PE 009-17), particles/m³

Grade≥ 0.5 µm≥ 5 µm
At restIn operationAt restIn operation
A3,520 (≈ ISO 5)3,520 (≈ ISO 5)Not specified*Not specified*
B3,520 (≈ ISO 5)352,000 (≈ ISO 7)Not specified*2,930
C352,000 (≈ ISO 7)3,520,000 (≈ ISO 8)2,93029,300
D3,520,000 (≈ ISO 8)Not predetermined (set by manufacturer)29,300Not predetermined (set by manufacturer)
Source: PIC/S PE 009-17 Annex 1 Table 1 (classification) · * 5 µm classification may be considered where indicated by the CCS or historical trends · In Thailand, the MOPH GMP notification B.E. 2569 allows Annex 1 to follow PE 009-16 until 31 December 2029; the ≥ 0.5 µm limits are the same, but the ≥ 5 µm limits differ. See the comparison table

Minimum number of sampling locations (ISO 14644-1:2015 Table A.1)

2

1

10

5

24

6

52

10

104

16

232

22

1,000

27
Source: ISO 14644-1:2015 Table A.1 (room area in m² → minimum number of locations). For rooms larger than 1,000 m², use Formula A.1 in the standard

Retest intervals

ISO 14644-2:2015 (particle classification)

12 months

PIC/S GMP Annex 1: Grade A, B

6 months

PIC/S GMP Annex 1: Grade C, D

12 months
Source: ISO 14644-2:2015 · PIC/S PE 009-17 Annex 1 clause 4.32 (maximum intervals) · Requalification is also required after remedial action or significant change